Amana Range AGG200AA User Manual

20" (50.8 cm) Freestanding Gas Range  
PRODUCT MODEL NUMBERS  
PRODUCT DIMENSIONS  
AGG200AA  
Type of Gas  
Natural gas:  
This range is design-certified by CSA International for use with Natural gas  
or, after proper conversion, for use with LP gas.  
This range is factory set for use with Natural gas. See “Gas Conversions”  
section. The model/serial rating plate located on the oven frame behind  
the left side of the broiler door has information on the types of gas that  
can be used. If the types of gas listed do not include the type of gas  
available, check with the local gas supplier.  
LP gas conversion:  
Conversion must be done by a qualified service technician.  
41¹¹⁄₁₂"  
(106.6 cm)  
No attempt shall be made to convert the appliance from the gas specified  
on the model/serial rating plate for use with a different gas without  
consulting the serving gas supplier. See “Gas Conversions” section.  
Gas Supply Line  
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location.  
A smaller size pipe on longer runs may result in insufficient gas supply.  
With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually,  
LP gas suppliers determine the size and materials used in the system.  
NOTE: Pipe-joint compounds that resist the action of LP gas must be  
used. Do not use TEFLON®† tape.  
Flexible metal appliance connector:  
25⁷⁄₈"  
(65.9 cm)  
19³⁄₄"  
(50 cm)  
If local codes permit, a new CSA design-certified, 4-5 ft (122-152.4 cm)  
long, ¹⁄₂" (1.3 cm) or ³⁄₄" (1.9 cm) I.D., flexible metal appliance connector  
may be used for connecting range to the gas supply line.  
A ¹⁄₂" (1.3 cm) male pipe thread is needed for connection to the female  
pipe threads of the inlet to the appliance pressure regulator.  
Do not kink or damage the flexible metal tubing when moving the range.  
Rigid pipe connection:  
The rigid pipe connection requires a combination of pipe fittings to obtain  
an in-line connection to the range. The rigid pipe must be level with the  
range connection. All strains must be removed from the supply and fuel  
lines so range will be level and in line.  
Must include a shutoff valve:  
The supply line must be equipped with a manual shutoff valve. This valve  
should be located in the same room but external to the range opening,  
such as an adjacent cabinet. It should be in a location that allows ease of  
opening and closing. Do not block access to shutoff valve. The valve is  
for turning on or shutting off gas to the range.  
B
A. Gas supply line  
B. Shutoff valve “open” position  
C. To range  
A
C
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.  
Page 1 of 2  
Because Whirlpool Corporation policy includes a continuous commitment to improve  
our products, we reserve the right to change materials and specifications without notice.  
Dimensions are for planning purposes only. For complete details, see Installation  
Instructions packed with product. Specifications subject to change without notice.  
Ref. W10531342A  
1/16/14  
 

3M Marine Instruments 48N User Manual
AEG Washer 50720 User Manual
Aiwa Stereo System Z VR55 User Manual
Alamo Lawn Mower 803213P User Manual
Alphasonik Car Speaker PSW810E User Manual
Amazon eBook Reader B0083PWAPW User Manual
Americana Appliances Freezer A3315ABR User Manual
American Audio Turntable TTD 2400 User Manual
Avenview Stereo System HDMI C5 4 User Manual
Avet Reels Fishing Equipment LX 60 User Manual